Lípová 15, 120 44 Praha 2 | Email: kvas@beerresearch.cz | Tel.: +420 224 900 129 | Fax: +420 224 290 618
Kvasny Prum. 1964; 10(5): 103-105 | DOI: 10.18832/kp1964017
The theoretical output of an ideal continuous malt kiln is calculated and its dependence upon various atmospheric parameters of ambient air is shown. The results of many calculations are presented in the form of a diagram permitting to find the consumption of air and heat per100 kgof dry malt for any atmospheric condition. The table will facilitate rough estimates preceding detailed calculations.
(In Czech, English summary only)
Published: May 1, 1964